LVDT accessories

eddylab provides various accessory products that are specially adapted to the individual series of LVDT sensors.

Connection cables, extension cables and connectors can be found in the ‘Universal accessories’ category.


Feeler heads

Probes are used with all LVDT sensors with a spring probe mechanism. They have an M2.5 thread with which they are screwed into the push rod of the sensors.They are therefore interchangeable. The different geometries allow measurement in narrow bores, for example, or spread the spring force of the sensor over a larger area. The probe tips are available in different materials.

FEELER-MODEL MATERIAL ORDER CODE
 Model 01  Steel  Tastkopf-01
   Carbide  Tastkopf-01-HM
   Ruby  Tastkopf-01-R
   Ceramic  Tastkopf-01-K
 Model 02  Steel  Tastkopf-02
   Carbide  Tastkopf-02-HM
 Model 03  Steel  Tastkopf-03
 Carbide  Tastkopf-03-HM
 Model 04  Steel  Tastkopf-04
 Model 05  Steel  Tastkopf-05
 Model measuring roller    Tastkopf-782.238

 

Gaiter

The bellows protects the sensor mechanism from dust and dirt. It is used in the SM series displacement transducers with a spring-loaded sensor mechanism. In addition to the gaiter, a set also includes all the fastening rings required for secure mounting. These sets can be used to retrofit a sensor without gaiter and as a replacement part for a damaged gaiter.

BESCHREIBUNG DETAILS BESTELLCODE
 Gaiter retrofit set SM2-T  For sensors with 2 mm Measuring range  Set-FB-2
 Gaiter retrofit set SM5-T  For sensors with 5 mm Measuring range  Set-FB-5
 Gaiter retrofit set SM10-T  For sensors with 10 mm Measuring range  Set-FB-10
 Gaiter retrofit set SM25-T  For sensors with 20 mm Measuring range  Set-FB-20
 Gaiter retrofit set SM25-T  For sensors with 25 mm Measuring range  Set-FB-25

 

Mounting accessories

>  For simple, convenient installation of the sensor using a clamping mechanism. Unlike a point-type clamping, for example using a radially mounted grub screw, the circumferential clamping does not damage the sensor housing. The sensor can be easily removed or axially adjusted at any time.
>  Foot clamps allow the sensor to be mounted at 90° to the fixing level.
>  Flange clamps are used to install the sensor parallel to the fixing level.
>  Clamping pieces are available in different versions, adapted to the diameter of the inductive sensors.
>  The available materials qualify the clamps for different operating temperatures

ORDER CODE DIAMETER MATERIAL
 Flange clamp 2030, Ø 20mm  20 mm  Reinforced polyamide
 Foot clamp 2030, Ø 20mm  20 mm  Reinforced polyamide
 Flange clamp 1218, Ø 12mm; 18mm  12 mm; 18 mm  Reinforced polyamide
 Foot clamp 1218, Ø 12mm; 18mm  12 mm; 18 mm  Reinforced polyamide
 Flange clamp 8-AL  8 mm  Aluminium
 Flange clamp 16-AL, Ø 16mm  16 mm  Aluminium
 Foot clamp 16-AL, Ø 16mm  16 mm  Aluminium
 Flange clamp 20-AL, Ø 20mm  20 mm  Aluminium
 Foot clamp 20-AL, Ø 20mm  20 mm  Aluminium
 Flange clamp 8-VA  8 mm  Stainless steel
 Flange clamp 12-VA, Ø 12mm  12 mm  Stainless steel
 Foot clamp 12-VA, Ø 12mm   12 mm  Stainless steel
 Flange clamp 20-VA, Ø 20mm  20 mm  Stainless steel
 Foot clamp 20-VA, Ø 20mm  20 mm  Stainless steel